Archi-Civilarchi-civil.com
TBDY 2018 · TBDY-06  |  Confidence: A

Home / Articles / TBDY 2018 TBDY-06

Storey Drift Limit: A Measure for Protecting Infill Walls

A building can stay standing in an earthquake while its walls collapse, its windows break and its doors jam. The TBDY storey drift limit exists to protect these non-structural elements, not the structure itself.

Confidence: A Engine: engine/tbdy-assessment.js Test: tests/tbdy-assessment.test.js Reading: ~9 min Last verified: 2026-10-21 Türkçe: Türkçe oku
Open the calculator →Next article → All articles →

1. What drift measures

Storey drift is the difference in horizontal displacement between the top and bottom slabs of a storey. Divided by the storey height, it shows how much the storey "racks". The structural system can usually tolerate this racking; the masonry infill inside the frame cannot. It cracks, breaks up and may collapse. A wall that blocks an escape route or falls on people is a life-safety problem even if the structure survives.

2. From reduced drift to real drift

Seismic analysis uses forces reduced by Ra (TBDY-01). The drift Δ obtained with these forces is smaller than the real drift. To approach the real value, Δ is scaled back up by the reduction ratio:

δi = (R / I) · Δi

This is a direct application of the "equal displacement" principle described in TBDY-01: the displacement of a yielding structure is about equal to that of an elastic structure with the same period.

Important: Δi must be computed with the reduced seismic loads but without the period limit of Clause 4.7.3.2 and the minimum base shear of Equation (4.19) (Clause 4.9.1.1). Those two conditions are for forces; they should not artificially inflate drift.

3. λ: why another hazard level?

The drift check is made not for the design earthquake (DD-2) but for a more frequent one: DD-3. The reasoning: damage to infill walls is acceptable in the design earthquake, but their collapse in a smaller earthquake that is likely to occur during the building's life is not. λ is the ratio of the spectral accelerations of the two levels:

λ = Sae(DD-3) / Sae(DD-2),   at the dominant period

λ is computed from the hazard map for the site; it is not a fixed number.

4. The limit: 0.008κ or 0.016κ

The check is (Clause 4.9.1):

λ · δi,max / hi ≤ 0.008 κ    (infill attached to the frame, Eq. 4.34a)
λ · δi,max / hi ≤ 0.016 κ    (infill flexibly connected, Eq. 4.34b)

Flexibly connected walls need not follow the frame's movement, so twice the drift is accepted. κ depends on the material: 1.0 for reinforced concrete and 0.5 for steel buildings.

5. Worked example

A 3 m storey, drift under reduced loads Δ = 4 mm, R = 8, I = 1, and λ = 0.5 as an example value (in a real project it comes from the site hazard map). With the site's engine:

Caseδ = (R/I)·Δ (mm)λ·δ/hLimitResult
RC, infill attached to frame320.00530.008passes
RC, infill flexibly connected320.00530.016passes
Steel, infill attached to frame320.00530.004fails

The same drift is within the limit for an RC frame and beyond it for a steel frame. κ = 0.5 halves the limit for steel buildings. Steel frames are usually more flexible and drift more for the same strength, so a tighter limit is needed to protect the infill.

6. Two points to watch

Try it on the site: the TBDY workflow tool runs the drift check storey by storey; material, infill connection and λ can all be changed.

References

  1. TBDY 2018 — Clause 2.2 (earthquake ground motion levels), Clauses 4.9.1 and 4.9.1.1, Equations (4.34a) and (4.34b), Clause 4.7.3.2, Equation (4.19). Official Gazette, 18.03.2018, No. 30364 (repeated).
  2. Table values computed with the drift() function of engine/tbdy-assessment.js (κ = 1.0 RC, 0.5 steel). λ = 0.5 is an example value.

The numbers in this article were produced by the site's engines; code values are given with their clause numbers.

archi-civil.com — Storey Drift Limit: A Measure for Protecting Infill Walls · TBDY-06 ·