Home / Articles / TBDY 2018 TBDY-05
Torsional Irregularity (A1): Why Does a Building Twist in an Earthquake?
A building whose centre of mass and centre of rigidity do not coincide does not only sway in an earthquake — it also twists. One edge is stressed far more than the other. TBDY captures this with a single ratio, ηbi. What happens when η > 2.0 is often misunderstood.
1. Why does a building twist?
The earthquake force acts on the building's mass and can be thought of as concentrated at the centre of mass. The building resists with its stiffness, whose "centre" depends on how the structural members are arranged in plan. If the two centres do not coincide, the earthquake also applies a torsional moment: the building both sways and twists.
The typical case is a building whose lift and stair walls are grouped in one corner of the plan. The edge with the walls moves little, the opposite edge a lot. Columns on the far edge are stressed much more than the average drift would suggest.
2. The torsional irregularity factor ηbi
TBDY 2018 defines this among the plan irregularities as A1 — torsional irregularity (Table 3.6). At each storey the largest storey drift in the earthquake direction is compared with the average:
If ηbi > 1.2 an A1 irregularity exists. With no torsion both edges drift equally and ηbi = 1.
3. The amplification factor Dbi
In buildings with torsional irregularity, the additional eccentricity used in analysis is amplified by a factor (Equation 4.29):
The values below were computed with the site's TBDY assessment engine:
| Δmax (mm) | Δmin (mm) | Δavg (mm) | ηbi | Irregular | Dbi |
|---|---|---|---|---|---|
| 12 | 8 | 10.0 | 1.20 | no | 1.0000 |
| 15 | 5 | 10.0 | 1.50 | yes | 1.5625 |
| 10 | -2 | 4.0 | 2.50 | yes | undefined (η > 2.0) |
In the first row ηbi is exactly 1.2: at the limit, but no irregularity. In the second, ηbi = 1.5 and the additional eccentricity is multiplied by (1.5/1.2)² = 1.5625.
4. When one edge moves backwards
The third row is instructive: Δmin = −2 mm. The building twists so much that the stiff edge moves against the earthquake direction. Δmin must then be entered as negative, giving ηbi = 10 / 4 = 2.5.
The detail looks small but changes the result. Clipping Δmin to zero would cap ηbi at 2.0; taking its absolute value would give 10 / 6 = 1.67. Both understate the real torsion. This error was found and fixed in the site's engine during a 2026 audit; the engine now handles negative Δmin correctly.
5. ηbi > 2.0: is it prohibited?
A common misconception: in TBDY 2018, torsional irregularity is not prohibited, however large. Under Clause 3.6.2.1 it only affects the choice of analysis method. But because the Dbi formula is defined only for ηbi ≤ 2.0, beyond that range there is no defined way to amplify the additional eccentricity in the equivalent lateral force method, and modal analysis is recommended.
The contrast with the weak-storey irregularity is useful: there, ηci < 0.60 is never accepted (TBDY-03). Torsion has no such absolute limit — but its absence does not make it good design.
6. What to do in design
The real remedy for torsional irregularity lies in the plan, not the calculation: placing walls and stiff members symmetrically, or at least spread towards the perimeter, brings the centre of rigidity closer to the centre of mass. Perimeter walls raise torsional stiffness most effectively because they are furthest from the axis of rotation.
References
- TBDY 2018 — Clause 3.6, Table 3.6 (A1 torsional irregularity), Clause 3.6.2.1, Equation (4.29), Table 4.4. Official Gazette, 18.03.2018, No. 30364 (repeated).
- Table values computed with the irregularities() function of engine/tbdy-assessment.js. Negative Δmin and η > 2.0 fixes: engine release notes (v334).
The numbers in this article were produced by the site's engines; code values are given with their clause numbers.