Home / Tools / Accessible Ramp (ADA) H · Accessibility
Accessible Ramp — 2010 ADA Standards §405
Number of runs and landings, run length, straight-ramp footprint and the §405 checks: running and cross slope, clear width, rise per run, landings and handrails.
Ramp
Results
Runs · rise per run · run length—
Landings · straight-ramp length (runs + landings)—
§405 compliance—
| § | Item | Limit | OK |
|---|
2010 ADA Standards§303.4, §403.3, §405.2–405.8, Table 405.2, §505 — U.S. Department of Justice (public domain). Interpretation per the U.S. Access Board Guide to the ADA Accessibility Standards, Chapter 4. State and local codes (IBC Chapter 11 / ICC A117.1, California CBC 11B) may be more stringent.
VerifiedHand calculations; the Access Board states there is no limit on total ramp length or number of runs — only the 30 in rise per run. A "30 ft maximum run" holds only at 1:12.
Preliminary calculation tool. Final design requires the full text of the referenced standard (see the sources on this page) and review by a licensed PE.