Turkish Zoning Regulation — Clause Reference
Site coverage and floor area ratios, lifts, stairs, ramps, minimum room sizes and parking demand, with clause numbers. Tables are read live from the calculation engine.
1. Site coverage and floor area ratio — Clauses 4, 22
Site coverage ratio: the ratio of building footprint to plot area. The footprint is computed by taking together the ground-floor projection and all basement storeys that remain above natural or finished ground because of site slope.
Floor area ratio: the ratio of the sum of all constructed floor areas to the plot area. Basements, mezzanines, habitable roof spaces and open or enclosed projections are included; areas excluded from the ratio are deducted.
2. Lifts — Clause 34
| Storeys | Requirement |
|---|---|
| 3 storeys | a lift shaft must be provided |
| 4 storeys and above | a lift must be installed |
| Lift type | Car short side | Car area | Door clear width |
|---|---|---|---|
| Building with a single lift | ≥ 1.20 m | ≥ 1.80 m² | ≥ 0.90 m |
| 10 storeys and above — goods/stretcher | ≥ 1.20 m | ≥ 2.52 m² | ≥ 1.10 m |
Clause 31: the landing onto which the lift door opens must be ≥ 1.20 m for sliding doors and ≥ 1.50 m for outward-opening doors.
3. Stairs — Clause 31
| Building | Max riser height |
|---|---|
| Buildings without a lift | 0.16 m |
| Buildings with a lift | 0.18 m |
Common stair flight and landing widths in dwellings are computed under the fire code.
4. Ramps — Clause 30(12)
The binding ramp gradients are here, in public law. TS 9111 also covers ramp gradients; where the two differ, the regulation in force governs.
| Rise | Max gradient | Percent | Min ramp run |
|---|---|---|---|
| loading… | |||
Where the rise exceeds 15 cm or the horizontal run exceeds 200 cm, guardrails are required on both sides; ramps wider than 300 cm need a central handrail.
The footprint is larger than intuition suggests: a rise of 80 cm needs at least 13.33 m of ramp, which exceeds the 9 m limit and therefore requires an intermediate landing; with landings it occupies 17.83 m on plan. The ramp simulation shows this live.
5. Minimum room sizes — Clause 29
| Room | Min short side | Min clear area |
|---|---|---|
| loading… | ||
Such a ratio may exist in the superseded regulation for unplanned areas or in local municipal by-laws. This page and the corresponding tool do not invent one.
Light-well rule: at most 4 rooms per storey may draw light from one minimum-size light well or air shaft; an air shaft is at least 0.60 × 0.60 m. In wet rooms without mechanical ventilation, the ventilation window must be ≥ 0.30 × 0.30 m clear.
6. Parking demand
| Use | Parking requirement |
|---|---|
| loading… | |
Electric vehicles: new buildings whose minimum required parking is 20 spaces or more must provide 5% as EV charging spaces (from 1/1/2023).