Clause numbers and numerical tables of Turkish building regulations, in one place. Every table is read live from its calculation engine, so the reference and the tool cannot drift apart.

How it is built The tables on these pages are not hand-written. They are read from the engines under engine/; the same data also feeds the calculation tools and is pinned by the test suite under tests/. If a regulation changes, only one place is updated.

Public regulations — full text may be given

The following are published in the Official Gazette; their clause text and tables appear here in full.

ReferenceSourceScopeEngine
Fire Code — Escape and Compartments RG 19/12/2007-26735 Occupant load (Annex 5/A) · unit width capacities and travel distances (Annex 5/B) · number of exits · compartment areas (Annex 4) fire-safety.js
Shelter Regulation OG 25/8/1988-19910
amended OG 7/11/2025-33070
Exemption thresholds (Clause 7) · occupant count (Clause 8) · area and construction requirements · threshold jumps shelter.js
Zoning Regulation RG 3/7/2017-30113 Site coverage / floor area ratio · lifts · stairs · ramp gradients · minimum room sizes · parking demand imar.js

Copyrighted standards — numerical requirements only

TS 825 and AISC 360 are copyrighted standards. The text of the standard is not reproduced here; numerical requirements and formula structure are given in our own words with clause references. For actual project use the standard itself governs.

TopicStandardConfidenceTool
Thermal insulation, degree-day zones, U-value limitsTS 825:2024 B heat loss tool
Fillet weld strength, throat, leg size limitsAISC 360 Chapter J2 B weld tool
The reason for confidence level B is stated on each tool's own page.

Other code calculations

TopicSourceTool
Seismic load combinationsTBDY 2018 Clause 4.4.4 load combinations
Snow, wind, ice and live loadsTS 498:2021 TS 498 tools

Simulations

Interactive simulations fed by the same engines. They show the counter-intuitive parts of the regulations by letting you play with them.

SimulationWhat it showsSource
Escape Route How occupant load, required width and exit count change with use class and area Fire Code Clauses 32-33, Annex 5
Compartment Value Why the same suppression system is worth something entirely different per occupancy Fire Code Clause 24, Annex 4
Ramp Reality The floor area a ramp really takes once landings are counted Zoning Regulation Clause 30(12)
Shelter Cliff That thresholds are cliffs, not gradients Shelter Regulation Clauses 7-8
Superseded value warning Many online sources present superseded values as if they were current. Three cases encountered on this site are flagged on the relevant pages and protected by the test suite:

Shelter: the residential exemption threshold is 10 units, not 12 (amendment of 7/11/2025).
Parking: for dwellings it is based on flat size, not "1 per 3 flats" (2018 amendment).
TS 825: six degree-day zones, not four; window U-value 1.8, not 2.4 (2024 revision).
Türkçe oku → Fire code reference → Zoning regulation reference → Simulations and games → Ana sayfa →